System Specifications

Technical Requirements in Joinery and Façade Systems
  • Profiles required by the suggested implementation should be chosen from the system manufacturer’s catalog.
  • Production should be made using 6060-6063 alloyed profiles that are suitable for anodic oxidation and that allow exact tolerance designs.
  • Leakproof and dust collecting cords should be E.P.D.M.
  • Flexible silicon or tiachol-based materials should be used to provide insulation.
  • For outside usage, A4 stainless steel visible screws and A2 stainless steel invisible screws should be preferred.
  • Heat insulation barriers should be made of polyamide.
  • Steel parts for anchors and reinforcement should be galvanized.
Accessory Specifications
  • Attached channel sizes and shapes are in accordance with EURO standards that determine systems’ case-wing relations.
  • Opening mechanisms such as handles, hinges, dual-axis etc. should be in full compliance with the system and should comprise technical specifications suggested by the system manufacturer.
  • Shapes of accessories to be placed in profile slots should be the same as those of profiles.
EPDM CONTA Malzeme Özellikleri ve Avantajları
  • Longevity: E.P.D.M. is an indispensable specification of gaskets. There is no alternative to E.P.D.M. when it comes to resistance to physical factors, temperature changes, aging, and other laboratory tests.
  • Resistance to ozone: Atmospheric ozone, which normally causes cracks in gaskets, does not harm E.P.D.M. gaskets.
  • Flexibility: Rate of deformation due to stretching, buckling, pressing, etc. is minimized in E.P.D.M. compared to other gaskets.
  • Resistance to abrasion: E.P.D.M. is more resistant to corrosion caused by friction.  

 

 

 

 

  E.P.D.M. GASKET’S TECHNICAL SPECIFICATIONS

HEAT INSULATION BARRIER Materials Report
Material : PA 66 GF 25 (polyamide with 25% glass fiber reinforced)
Shape resistance : 250 ± 5 °C
Density : 1,3 ± 0.05 g / cm
Firmness : 84 ± 2 Shore
K-value : 0,32 W / m.K

 

Specifications Unit DIN-Norm Values
Implementation Values
E-Module N / mm² 7.300 – 8.000 ( DIN 53457 )
min. 2.900
Bending Strength N / mm² 120 ( DIN 53455 )
min.  80
Stretching Strength N / mm² 170 ( DIN 53452 )
min.  80
Impact Strength kJ / m² 35 ( DIN 53453 )
30 kJ / m²

Joinery Systems Heat Permeability Diagram

Test Reports – 1 İTÜ (İstanbul Technical University) Heat Permeability Coefficient Assessment

.

Air Escape EN 12207
Water Escape EN 12208
Portion EN 12210

Normlara uygunluğu test raporları ile belirlenmiştir. ( Turkcesi verilmemis )

Test Raports -2 Yalıtımlı Doğrama Sistemi

Air Escape EN 12207
Water Escape EN 12208
Portion EN 12210

Normlara uygunluğu test raporları ile belirlenmiştir.

 

Foreign Exchange

USD
Purchase Sale
1.4936
1.5008
Euro
Purchase Sale
1.9252
1.9345
 

divide

Newsletter

Click here for subscription