COVERED SIDING SYSTEM
Profile thickness : 50 mm
Profile width : 1.8 mm – 3.0 mm
Vertical and horizontal bearing profiles (8 types for each) based upon static calculations
Heat-insulated and not insulated cassette profiles, hidden wing implementations
Discharge via condensate channel
Composite panel and finishing implementation details
In-façade aluminum joinery implementations
Horizontal tie assembly (with alternatives)
Glass thickness : 6 mm – 50 mm
All cords are E.P.D.M.
Vulcanized corner cord implementations for E.P.D.Ms
EURO-standard accessory implementations
| TECHNICAL SPECIFICATIONS | |||
| ALUMINUM PROFILE | ALLOY | TEMP. | HEAT INSULATION BARRIERS |
| TS 5246 EN 12020-2 | AlMgSi 0.5 | F22 | 14.8 mm 24 mm Polyamide 6.6 |
| TEST CLASSIFICATION | ||
| Air Escape | Water Escape | Portion |
| EN 12207 | EN 12208 | EN 12210 |
Vertical + Horizontal Cords – Lower-Upper Cover Joint :
Water coming from vertical cord is transferred to horizontal cord via condense channel and then discharged from the building.
PVC or E.P.D.M. joints are used to prevent metal-metal joints between vertical-horizontal and to provide sound and heat insulation.

Drainage (Condense) Channel and Horizontal Tie Joint :
In horizontal and vertical tie assembly, E.P.D.M. cords, and lower cover assembly, it is important that horizontal cover profile is dropper-type and does not cause level difference with vertical profile (for aesthetic purpose).


Assembly of all main elements with glass Detail of vertical dilatation that allows joining two vertical profiles